TECHNICAL
SPECIFICATION OF OIL FIRED STEAM BOILER
|
||||||||
| Details | Unit |
EP-01
|
EP-02
|
EP-03
|
EP-04
|
EP-05
|
EP-06
|
EP-08
|
| OPERATION DETAILS : | ||||||||
| Rated Steam Output F & A 100°C | Kgs/Hr |
100
|
200
|
300
|
400
|
500
|
600
|
800
|
| Steam Pressure Maximum | Kgs/Hr |
15
|
15
|
15
|
15
|
15
|
15
|
15
|
| Thermal Efficiency |
----------> On G.C.V.
87 % ON N.C.V 96%<----------
|
|||||||
| Steam Temperature |
-
|
|||||||
| Fuel Oil Consumption LDO | Kgs/Hr | 6 | 12 | 18 | 24 | 30 | 36 | 48 |
| Fuel Oil Consumption FO | Kgs/Hr | - | - | 19.1 | 25.4 | 31.6 | 38.1 | 50.8 |
| Burner Control |
----------> ON- OFF<----------
|
|||||||
| Pressure Parts |
OUTSIDE THE PURVIEW OF INDIAN
BOILER REGULATION
|
|||||||
| Electric Supply : |
-
|
|||||||
| Feed Water Pump Motor |
HP
|
0.5
|
0.5
|
1
|
1
|
1
|
1
|
1
|
| Blower + Fuel pump motor |
HP
|
1.5
|
1.5
|
2
|
2
|
2
|
2
|
3
|
| Fuel Oil preheater (if F.O. Use) |
Kw
|
-
|
-
|
3
|
3
|
3
|
3
|
6
|
| Total Electrical Load for |
-
|
|||||||
| LDO Fired Units |
-
|
2 HP
|
2 HP
|
3 HP
|
3 HP
|
3 HP
|
3 HP
|
4 HP
|
| FO Fired Units |
-
|
-
|
-
|
3HP+3KW | 3HP+3KW | 3HP+3KW | 3HP+3KW | 4HP+6KW |
| Flue Gas Outlet |
Mm
|
150
|
150
|
200
|
200
|
200
|
250
|
300
|
| Dry Weight(approx) |
Kgs.
|
1000
|
1100
|
1300
|
1400
|
1600
|
1700
|
1800
|

Factory:Plot
29,GIDC N.H.No. 8, POR - Ramangamdi.Ta.
Dist Vadodara
- 391243. Ph : +91- 0265 - 830375 , 831079
Fax :+91-0265-830975. E
- mail : info@energy-boilers.com
energyboiler@satyam.net.in